  239 03/01 3-line filters b84143-g*-r112 b84143-g*-r110 for converters and power electronics power line filters for three-phase systems rated voltage 480/275 and 520/300 v~, 50/60 hz rated current 8 to 220 a construction three-line filter metal case book size features high insertion loss low leakage current optimized footprint saves space litz wires on the load side reduce mounting time low weight degree of protection: ip 20 1) design based on en 133 200, csa 22.2 no.8 1986 optimized for long motor cables and operation under full load ul 1283 approval for type -r110 , for -r112 ul and csa approval pending applications frequency converters for motor drives, e.g. ? elevators ? pumps ? traction systems ? conveyor systems ? hvac systems (heating, ventilation and air conditioning) wind farms power supplies terminals line: safe-to-touch terminal blocks load: litz wires marking marking on component: manufacturer ? s logo, ordering code, rated voltage, rated current, rated temperature, date code minimum marking on packaging: manufacturer ? s logo, ordering code 1) in accordance with iec 60529:1989; en 60529:1991; din vde 0470-1
240 03/01 3-line filters b84143-g*-r112 b84143-g*-r110 for converters and power electronics typical circuit diagrams b84143-g8 ? g20-r110/-r112 b84143-g36 ? g220-r110/-r112 l1 l3 ssb1286-z l2 l2 ? l3 ? l1 ? line load l1 l3 ssb1287-8 l2 l2 ? l3 ? l1 ? line load
241 03/01 3-line filters b84143-g*-r112 b84143-g*-r110 for converters and power electronics technical data characteristics and ordering codes compilation of ordering code replace the asterisk * by the code number for the required version: 0 = 480 / 275 v 2 = 520 / 300 v 1) at rated operation rated voltage v r 480/275 v~, 50/60 hz (type -r110) 520/300 v~, 50/60 hz (type -r112) rated current i r referred to 40 c ambient temperature test voltage v p 1770 v ? , 2 s (line/line) 2700 v ? , 2 s (lines/case) overload capability 1,5 i r for 3 min per hour or 2,5 i r for 30 s per hour leakage current i leak at 480 v~, 50 hz climatic category 25/100/21 ( ? 25 c/+ 100 c/21 days damp heat test) in accordance with en 60068-1 i r a terminal cross section i leak r typ m ? approx. weight kg ordering code line side: terminal blocks mm 2 load side: litz wires mm 2 typ. 1) ma 84 1,5 < 6 40 1,3 B84143-G8-R11* 20 4 2,5 < 6 10 1,3 b84143-g20-r11* 36 6 6,0 < 16 5,2 2,8 b84143-g36-r11* 50 16 10 < 16 2,4 3,3 b84143-g50-r11* 66 25 16 < 16 1,8 4,4 b84143-g66-r11* 90 25 25 < 16 1,2 4,9 b84143-g90-r11* 120 50 35 < 16 1,0 7,5 b84143-g120-r11* 150 50 35 < 16 0,7 8,0 b84143-g150-r11* 220 95 70 < 16 0,4 11,5 b84143-g220-r11*
242 03/01 3-line filters b84143-g*-r112 b84143-g*-r110 for converters and power electronics dimensional drawings B84143-G8-R11*, b84143-g20-r11* b84143-g36-r11* ssb1291-1 marking 200 50 80 40 250,3 6,5 46 anschluss- klemmen 4 mm m6 x 25 pe 15 31 30010 pe l3 ? l2 ? l1 ? 1 0,5 2150,5 230 aderendh lse litzenbezeichnung litze l2 l1 l3 line load 2 terminal blocks 4 mm 2 litz wire litz wire markings wire end ferrule ssb1292-9 150 75 60 marking 350,3 6,5 56 2650,5 280 m6 x 25 30 pe 60 250 40010 0,5 1 l2 l1 l3 klemmen 6 mm anschluss- litze litzenbezeichnung aderendh lse l3 ? l2 ? l1 ? pe line load 2 terminal blocks 6 mm 2 litz wire litz wire markings wire end ferrule
243 03/01 3-line filters b84143-g*-r112 b84143-g*-r110 for converters and power electronics b84143-g50-r11* b84143-g66-r11*, b84143-g90-r11* ssb1293-h 300 30 0,5 1 pe m6 x 25 50010 litze marking 3150,5 56 350,3 6,5 330 klemmen 16 mm anschluss- 52 l1 l2 l3 litzenbezeichnung aderendh lse l3 ? l2 ? l1 ? pe 150 60 75 line load 2 terminal blocks 16 mm 2 litz wire litz wire markings wire end ferrule ssb1294-q 80 150 75 30 pe m10 x 35 300 3150,5 1 0,5 marking 50010 litze 330 6,5 550,3 76 52 anschluss- klemmen 25 mm l3 ? l2 ? l1 ? pe litzenbezeichnung aderendh lse line load 2 l1 l3 l2 terminal blocks 25 mm 2 litz wire litz wire markings wire end ferrule
244 03/01 3-line filters b84143-g*-r112 b84143-g*-r110 for converters and power electronics b84143-g120-r11*, b84143-g150-r11* b84143-g220-r11* ssb1295-y 90 200 100 40 pe m10 x 35 350 50010 0,5 1 3650,5 litze 380 650,3 86 6,5 klemmen anschluss- 78 l3 l1 l2 marking litzenbezeichnung aderendh lse l3 ? l2 ? l1 ? pe line load 50 mm 2 terminal blocks litz wire litz wire markings wire end ferrule 50 mm 2 ssb1348-t 110 220 110 anschlussklemmen 95 mm pe m10 x 35 79 30 400 50010 litze aderendh lse 0,5 1 litzenbezeichnung 430 4150,5 6,5 850,3 106 marking line load 2 l3 ? l2 ? l1 ? pe l1 l3 l2 terminal blocks 95 mm 2 litz wire litz wire markings wire end ferrule
245 03/01 3-line filters b84143-g*-r112 b84143-g*-r110 for converters and power electronics insertion loss (typical values at z = 50 ? ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) B84143-G8-R11* b84143-g20-r11* b84143-g36 ? g220-r11* ssb1288-g 10 4 f hz 5 10 10 6 10 7 10 8 0 db 120 20 40 60 80 100 e ssb1289-p 10 4 f hz 5 10 10 6 10 7 10 8 0 db 120 20 40 60 80 100 e ssb1290-s 10 4 f hz 5 10 10 6 10 7 10 8 0 db 120 20 40 60 80 100 e
1 herausgegeben von epcos ag marketing kommunikation, postfach 80 17 09, 81617 mnchen, deutschland ? epcos ag 2000. alle rechte vorbehalten. vervielf ? ltigung, ver ? ffentlichung, verbreitung und verwertung dieser brosch re und ihres inhalts ohne ausdr ckliche genehmigung der epcos ag nicht gestattet. mit den angaben in dieser brosch re werden die bauelemente spezifiziert, keine eigenschaften zugesichert. bestellungen unterliegen den vom zvei empfohlenen allgemeinen lieferbedingungen f r erzeugnisse und leistungen der elektroindustrie, soweit nichts anderes vereinbart wird. diese brosch re ersetzt die vorige ausgabe. fragen ber technik, preise und lieferm ? glichkeiten richten sie bitte an den ihnen n ? chstgele- genen vertrieb der epcos ag oder an unsere vertriebsgesellschaften im ausland. bauelemente k ? nnen aufgrund technischer erfordernisse gefahrstoffe enthalten. ausk nfte dar ber bitten wir unter angabe des betreffenden typs ebenfalls ber die zust ? ndige vertriebsge- sellschaft einzuholen. published by epcos ag marketing communications, p.o. box 80 17 09, 81617 munich, germany ? epcos ag 2000. all rights reserved. reproduction, publication and dissemination of this bro- chure and the information contained therein without epcos ? prior express consent is prohibited. the information contained in this brochure describes the type of component and shall not be con- sidered as guaranteed characteristics. purchase orders are subject to the general conditions for the supply of products and services of the electrical and electronics industry recommended by the zvei (german electrical and electronic manufacturers ? association), unless otherwise agreed. this brochure replaces the previous edition. for questions on technology, prices and delivery please contact the sales offices of epcos ag or the international representatives. due to technical requirements components may contain dangerous substances. for information on the type in question please also contact one of our sales offices.


▲Up To Search▲   

 
Price & Availability of B84143-G8-R11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X